Average: 0
Rating Count: 0

Development status: New development
Information status: New
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/GreatEyesGEVAC2048
Contact:



Class Description


Class for controlling the in-vacuum CCD camera model GE-VAC 2048 2048 BI from GreatEyes

Families: Acquisition

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: GreatEyes

Product:

GE-VAC 2048 2048 BI

Bus: USB

Class interface


Attributes:

Name Description
ImageImage: DevUShort
BiasCorrectionScalar: DevLong 0 -> disable, 1->enable
FileStartNumScalar: DevLong The file number used when saviing an image.
FilePrefixScalar: DevString The prefix of the image files to be created. The full image file name will be composed as <br /> <b>prefix_number.postfix </b> <br /> when acquiring images.
FileDirScalar: DevString Path to the dector image files.
BacksideTemperatureScalar: DevLong
SensorTemperatureScalar: DevLong
CoolingOffOnScalar: DevLong Switch temperature control off/on (0/1)
CoolingTemperatureLevelScalar: DevLong Adjust temperature of CCD sensoR
CropModeScalar: DevLong 1 -> active
CropModeYScalar: DevLong Number of lines to readout
CropModeXScalar: DevLong Number of columns to readout
CapacityModeScalar: DevLong 0 -> Standard ( Low Noise ) 1 -> Extended ( High Signal )
GainScalar: DevLong 0 -> Low ( Max. Dyn. Range ) 1 -> Std ( High Sensitivity )
BinningYScalar: DevLong Number of pixels [1...numPixelInY] to be binned in y-direction. 0 -> no binning
BinningXScalar: DevLong Number of pixels [1...numPixelInX] to be binned in x-direction (if supported by CCD). 0 -> no binning
ExposureTimeScalar: DevDouble Set exposure time, read last set value.
ReadoutSpeedScalar: DevLong Set readout speed. Read last set value. Sets pixel clock to [0..6] 0 -> 1 MHz 3 -> 3 MHz 5 -> 500 kHz 6 -> 50 kHz

Commands:

Name Description
PrepareAcqInput: DevVoid
Output: DevVoid
Update settings. Automatically called if settings have been changed and StartAcq is called before preparing the acquisition.
StopAcqInput: DevVoid
Output: DevVoid
Stop acquisition
StartAcqInput: DevVoid
Output: DevVoid
Start acquisition
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.

Pipes:

Properties:


Please log in to comment.

Feb. 9, 2019, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:9 Feb 2019, 4:02 a.m.