.

Average: 0
Rating Count: 0

Development status: Released, Release: Release_1_0
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Keithley/Keithley2602B
Contact:



Class Description


Class for controlling a channel of the Keithley2602B

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: Keithley

Product:

2602B

Bus: Ethernet

Class interface


Attributes:

Name Description
MeasVoltageScalar: DevDouble Measured voltage
MeasCurrentScalar: DevDouble Measured current
MeasIntegrationTimeScalar: DevDouble Set integration time in number of power line cycles, i.e. for 50Hz value 1 corresponds to 1/50Hz=20ms
MeasVoltAutoRangeScalar: DevLong switch autorange for voltage measurement on (1) or off (0). 2 -> automatically set
MeasVoltRangeScalar: DevDouble Range for voltage measurement
MeasCurrAutoRangeScalar: DevLong switch autorange for current measurement on (1) or off (0). 2 -> automatically set
MeasCurrRangeScalar: DevDouble Range for current measurement
SourceStateScalar: DevLong Switch the source output on (1) or off (0) or turn off the output in high Z mode (allows you to go to high Z mode without first setting the smuX.source.offmode attribute to smuX.OUTPUT_HIGH_Z)
SourceFuncScalar: DevString Selected source. Possible values: VOLTage, CURRent
SourceVoltageScalar: DevDouble Set voltage source amplitude
SourceLimitCurrScalar: DevDouble Liimit the current output of the voltage source
SourceVoltAutoRangeScalar: DevLong Switch autorange for voltage source on (1) or off (0)
SourceVoltRangeScalar: DevDouble Range for voltage source
SourceCurrentScalar: DevDouble Set current source amplitude
SourceLimitVoltScalar: DevDouble Liimit the voltage output of the current source
SourceCurrAutoRangeScalar: DevLong Switch autorange for current source on (1) or off (0)
SourceCurrRangeScalar: DevDouble Range for current source

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
CtrlDeviceDevString Name of the Tango Device connecting to the hardware
ChannelDevString a or b


Please log in to comment.

10 Nov 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Oct 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Oct 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Sep 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:15 Sep 2018, 3:38 a.m.