.

Average: 0
Rating Count: 0

Development status: Released, Release: latest
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/MythenWAXS
Contact:



Class Description


Manage a pool of Mythen2 detectors

Families: Acquisition

Key words:

Platform: All Platforms

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: SOLEIL

Bus: Not Applicable

Class interface


Attributes:

Name Description
badChannelInterpolationScalar: DevBoolean
energyScalar: DevFloat
thresholdScalar: DevFloat
exposureTimeScalar: DevDouble
nbFramesScalar: DevLong
flatFieldCorrectionScalar: DevBoolean
rateCorrectionScalar: DevBoolean
nbModulesScalar: DevLong
nbChannelsScalar: DevLong
frameXSpectrum: DevFloat
frameYSpectrum: DevFloat

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
SnapInput: DevVoid
Output: DevVoid
Arm/Start the acquisition.
StopInput: DevVoid
Output: DevVoid

Pipes:

Properties:

Name Description
ProxyNbRetryDevULong
ProxyMythenNamesArray of DevString A list of a proxies name to Myhten2Detector devices
ProxyMotorNameDevString
EquationParametersArray of DevString
PixelSizeDevFloat Mythen2 Detector pixel size (in mm)
AutoWriteHardwareAtInitDevBoolean Enable/Disable write hardware at init (energy/threshold/...)
MemorizedEnergyDevFloat Memorized Energy
MemorizedThresholdDevFloat Memorized Threshold
MemorizedExposureTimeDevDouble Memorized ExposureTime
MemorizedNbFramesDevLong Memorized NbFrames
MemorizedFlatFieldCorrectionDevBoolean Memorized FlatFieldCorrection
MemorizedRateCorrectionDevBoolean Memorized RateCorrection
MemorizedBadChannelInterpolationDevBoolean Memorized BadChannelInterpolation


Please log in to comment.

19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Feb 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:10 Feb 2018, 3:03 a.m.